Troubleshooting the Atlas Copco Ga22 Air Compressor can initially seem like a daunting task. But don’t worry, with a systematic approach, I’ve found that we can identify and address any issues in no time.


Over the years, I’ve encountered problems ranging from pressure or temperature discrepancies to more complex internal failures.


By carefully understanding compressor faults, utilizing the comprehensive manual, and adhering to safety guidelines, we can often restore optimal function to this powerful machine that plays an instrumental role in our day-to-day operations.


I’m here to guide you every step of the way. Let’s conquer this challenge together!


Atlas Copco Ga22 Troubleshooting


Atlas Copco Ga22 Troubleshooting:



When troubleshooting your Atlas Copco Ga22 Air Compressor, it’s crucial to start with the basics.

Check the power supply for any disruptions. If the compressor fails to start, inspect the motor starter for faults.

If the starter is functioning correctly, check the pressure switch wiring.

Make sure all electrical components are securely connected and that the circuit breaker is in a closed position.

Replacing any faulty parts should restore power to your compressor.

Ensure you refer to the user manual for detailed instructions on troubleshooting and resolving issues with your air compressor.


20 Common Atlas Copco Ga22 Air Compressor Problems And Solutions:


1. Overheating:

This could be due to insufficient ventilation, dirty coolers, or high ambient temperature. Ensure the machine is installed in a well-ventilated area, regularly clean the coolers and check the room temperature.


2. Low Oil Level:

Regularly check and refill the oil to the recommended level.


3. High Oil Level:

Drain the excess oil to avoid damage.


4. Compressor Not Starting:

Possible causes could be power failure, emergency stop is pressed, or motor overload. Check your power supply, reset the emergency stop and inspect for motor overload.


5. Excessive Noise:

It could be due to loose parts or worn out elements. Tighten any loose parts and replace worn-out elements.


6. Air Leaks:

Regularly inspect for leaks and fix any found.


7. Faulty Pressure Switch:

A faulty pressure switch may cause the compressor to run continuously. Replace the pressure switch if faulty.


8. Insufficient Air Pressure:

This could be due to a clogged air filter or a worn out valve. Clean or replace the air filter and valve if necessary.


9. High Air Consumption:

Check for leaks and fix them. If the high consumption continues, it may be time to upgrade to a larger model.


10. Compressor Vibrations:

This could be due to misalignment, looseness or imbalance. Check all parts and make necessary adjustments.


11. Slow Pressure Buildup:

Possible causes could be leaks, clogged filters, or worn out valves. Check for these issues and fix accordingly.


12. Pressure Does Not Reach Cut-off Point:

This could be due to a faulty pressure switch or a leak in the system. Check and fix these components.


13. Oil in Air Lines:

This could be due to faulty separators. Replace the separators if faulty.


14. Motor Failure:

Overloading or overheating can cause motor failure. Prevent this by regular maintenance and avoiding overload.


15. Compressor is Not Loading:

This could be due to a faulty solenoid valve. Check and replace the solenoid valve if necessary.


16. Excessive Moisture in the Air:

This could be due to high ambient humidity. Use an air dryer to solve this problem.


17. Failure of Safety Valve:

If the safety valve doesn’t operate, it may be stuck or damaged. Check and replace if necessary.


18. Compressor Shuts Down Randomly:

This could be due to overheating, power issues or other system faults. Check the system and fix any issues found.


19. Decreased Compressor Performance Over Time:

Regular maintenance and timely replacement of worn out parts can prevent this.


20. Faulty Control System:

If the control system is not functioning properly, check for faulty wiring or sensors and replace them as needed.


Atlas Copco Ga22 Compressor Fault Codes:

When it comes to Atlas Copco compressors, understanding fault codes can be crucial for efficient operation and maintenance.


Download the Atlas Copco compressor fault codes PDF to view the list of common codes and their descriptions.




Benefits Of Troubleshooting Atlas Copco Ga22 Air Compressor:

Troubleshooting your Atlas Copco Ga22 Air Compressor offers a host of benefits.


It aids in the early detection of potential issues, allowing you to address them promptly and prevent costly repairs or replacements down the line.


Moreover, it helps in maintaining optimum performance levels of the compressor, ensuring that it runs efficiently and effectively for your operations.


Regular troubleshooting also prolongs the lifespan of your compressor, giving you a better return on investment.


Lastly, it ensures safety, averting any compressor-related accidents due to malfunctioning or faulty components.


Maintenance Tips For Your Atlas Copco Ga22 Air Compressor:

To maintain the efficiency and longevity of your Atlas Copco Ga22 Air Compressor, follow these tips:


1. Regular Inspection:

Regularly inspect the motor and other mechanical components of the air compressor for any signs of wear and tear.


2. Clean Filters:

Ensure that the air filter is clean. A dirty filter can reduce the efficiency of your compressor and cause damage to the system. Replace filters as per the manufacturer’s guidelines.


3. Check oil levels:

Regularly check and maintain correct oil levels. This ensures smooth operation of the compressor and prevents overheating.


4. Ensure proper ventilation:

Proper ventilation reduces the chances of the compressor overheating, thereby extending its lifespan.


5. Regular servicing:

Make sure your compressor is serviced by a professional at recommended intervals. Regular servicing will help preempt and rectify any potential issues.


Remember, proactive maintenance of your Atlas Copco Ga22 Air Compressor can help in avoiding sudden shutdowns, extending the lifespan of the compressor, and reducing repair costs.


How Do I Reset My Atlas Copco Ga22 Compressor?

To reset your Atlas Copco Ga22 Compressor, follow these steps:


1. Locate the control panel on your compressor. It’s usually at the front of the machine.


2. Find the ‘Reset’ button. This is typically marked clearly, often with a red or orange color for easy identification.


3. Push the ‘Reset’ button. This should restart the system and clear any minor faults.


4. Monitor your compressor. After resetting, check the operation of your compressor to ensure that it is functioning properly.


Remember, if your compressor continues to show signs of malfunction after a reset, you should consult a professional for further assistance.


It may indicate a more serious issue that needs to be addressed promptly to prevent damage to your compressor.


How Do I Know If My Atlas Copco Ga22 Air Compressor Is Bad?

Determining if your Atlas Copco GA22 Air Compressor is malfunctioning involves checking for a number of warning signs.


First, if the compressor is not able to reach the necessary pressure level or takes an unusually long time to fill, this could be an indication of a problem.


Second, if your compressor is excessively noisy or vibrates heavily during operation, this might suggest mechanical issues.


Third, notice if the compressor frequently overheats or requires constant resetting, as these can be symptoms of malfunctioning.


Finally, check for any leaks, as this is a clear sign of a bad compressor. Consistent issues despite regular maintenance and troubleshooting warrant a consultation with a professional.


What Would Cause A Atlas Copco Ga22 Air Compressor To Not Build Pressure?

Several factors might cause your Atlas Copco Ga22 air compressor not to build pressure adequately.


1. Air Leaks:

Checks for any air leaks in the system. Leaks in the hoses or connections can prevent the compressor from building up sufficient pressure.


2. Valve Issues:

If the valves are worn out or damaged, they might not close properly, leading to pressure loss.


3. Air Filter Issues:

A clogged air filter may restrict airflow into the compressor, causing it not to build up pressure.


4. Worn Seals:

Seals and gaskets that are worn out or damaged can result in pressure loss.


5. Pump Issues:

Problems with the pump, such as worn or damaged components, can impact the compressor’s ability to build pressure.


If you observe any of these issues, it’s highly recommended that you seek professional assistance for repairs to prevent further damage to your compressor.


Atlas Copco Ga22 Air Compressor Won’t Start:

If your Atlas Copco Ga22 Air Compressor won’t start, there are several potential causes that you can investigate:


1. Power Supply:

First, check if your compressor is properly connected to the power supply. Ensure the plug is securely inserted into the socket and the switch is turned on. If you’re using an extension cord, make sure it is in good condition and suitable for the power requirements of the compressor.


2. Motor Issues:

If the motor isn’t starting, there could be an issue with the motor itself or its components. This can include problems with the motor winding, starting capacitor, or start relay. This generally requires a professional check-up.


3. Pressure Switch:

The pressure switch might be faulty or improperly adjusted, prompting the compressor not to start. You can try resetting the pressure switch to see if this resolves the issue.


4. Thermal Overload:

Compressors have a built-in safety mechanism that shuts the unit off if it overheats. If your compressor won’t start, it might be because the motor has overheated and the thermal overload switch has triggered.


Let the compressor cool down before trying to start it again. If the compressor still doesn’t start after you’ve checked these possible causes, it’s recommended to contact a professional for assistance.


It’s important not to attempt major repairs yourself, as improper handling can cause further damage to the unit or risk personal injury.


Atlas Copco Ga22 Air Compressor Not Building Pressure:

If your Atlas Copco Ga22 Air Compressor is not building pressure, the issue can be due to a variety of factors:


1. Air leaks:

One of the most common causes of pressure problems is air leaks. Check all hoses, fittings, and seals for signs of damage or wear and tear, and replace any that are faulty.


2. Valve issues:

Worn, damaged, or sticking valves can prevent the compressor from building pressure. Inspect and clean the valves regularly, and replace them if necessary.


3. Poor pump performance:

A poorly performing pump can hinder pressure buildup. This could be due to worn cylinders or piston rings, or a problem with the pump seals.


4. Other components:

Other compressor components, such as a clogged air filter or an improperly functioning pressure switch, can also cause pressure problems.


It is essential to conduct regular maintenance and checks on your compressor to prevent these issues.


If your compressor still does not build pressure after troubleshooting these issues, it is recommended to consult with a professional.


Atlas Copco Ga22 Air Compressor Reset Button:

The reset button on your Atlas Copco Ga22 Air Compressor is a crucial feature designed to deal with minor faults and disruptions that might occur during operation.


If your compressor is not working as expected or displays an error, you can try resetting it.


The reset button is usually colored red or orange for easy identification. Press this button to restart the system and clear any minor faults.


Always monitor your compressor after resetting to ensure that it resumes normal operation.


If the issues persist even after resetting, it’s recommended to seek professional help as there could be a serious underlying problem.


Atlas Copco Ga22 Air Compressor Won’t Turn On:

If your Atlas Copco Ga22 Air Compressor won’t turn on, a few potential issues could be the cause.

Electrical Faults: Ensure that the power source is correctly connected and the power cord is in good condition. Circuit breakers or fuses could have tripped due to an electrical overload, so make sure to check them as well.

Motor Overheating: Overheating can trigger the thermal overload switch, causing the compressor to shut down until it cools. Waiting for a while and then attempting to restart the device might solve the problem.

Pressure Switch: If the pressure switch is malfunctioning or improperly set, it could prevent the compressor from turning on. A professional should inspect this.


If you’ve investigated these issues and the compressor still won’t turn on, it’s recommended to contact a professional.


Please remember that attempting major repairs without professional guidance can cause further damage and personal injury.


Atlas Copco Ga22 Air Compressor Check Valve Problem:

The check valve, a crucial component in your Atlas Copco Ga22 Air Compressor, ensures the air flows in the correct direction within the system.


If this valve malfunctions, it could lead to several problems, including pressure buildup in the compressor when it is off or a continuous air leak.


Common signs of a faulty check valve include the motor struggling to start, or the release of air when the compressor shuts off.


If you suspect a problem with the check valve, professional inspection and servicing are recommended.


Remember, tampering with the compressor without proper knowledge can lead to further damage and potential safety risks.


Atlas Copco Ga22 Air Compressor Cleaning Tips:

Cleaning your Atlas Copco Ga22 Air Compressor is essential for its efficient operation and longevity. Here are some tips to keep your compressor clean:


1. Exterior Cleaning:

Dust and grime can accumulate on the exterior of your compressor over time. Use a soft, damp cloth to wipe down the exterior, making sure to avoid any delicate components.


2. Air Filter Cleaning:

The air filter should be inspected regularly and cleaned or replaced as needed. If the filter is clogged, it can lead to decreased performance and increased energy consumption.


3. Drain Moisture:

Make sure to regularly drain any accumulated moisture from the tank. Built-up moisture can lead to rust and corrosion inside the tank, which can adversely affect the compressor’s performance.


4. Clean Intake Vents:

Regularly check and clean the intake vents to ensure they are free from dust or other obstructions.


Remember to disconnect the compressor from the power source before performing any cleaning tasks.


Regular cleaning will help keep your Atlas Copco Ga22 Air Compressor running efficiently and prolong its lifespan.


Atlas Copco Ga22 Air Compressor Lubrication Tips:

Regular and proper lubrication is essential for the smooth operation of your Atlas Copco Ga22 Air Compressor. Here are some tips for lubricating your compressor:


1. Select the Right Lubricant:

Use only the lubricant recommended by Atlas Copco for your specific model. Using the wrong type can cause damage to your compressor.


2. Check Lubrication Regularly:

Regularly check the oil level in your compressor. It should never fall below the minimum level indicated on the sight glass.


3. Change Oil Periodically:

The oil in your compressor should be changed according to the manufacturer’s recommended maintenance schedule, or when it appears dirty or has lost its lubricating properties.


4. Inspect for Oil Leaks:

Regularly inspect your compressor for any signs of oil leaks. If leaks are found, they should be addressed immediately to prevent damage to your compressor.


5. Lubricate Other Components:

Other components such as the motor and pump also require regular lubrication. Refer to the manufacturer’s guidelines for specific instructions.


Remember, improper lubrication can lead to premature wear and tear, reduced performance, and potentially severe damage to your compressor.


Regular maintenance, including proper lubrication, will ensure that your Atlas Copco Ga22 Air Compressor operates efficiently and lasts for many years.


Storing Your Atlas Copco Ga22 Air Compressor:

Proper storage of your Atlas Copco Ga22 Air Compressor can significantly extend its lifespan and maintain its performance. Here are some tips to consider:


1. Clean Before Storage:

Prior to storage, clean the compressor thoroughly, following the cleaning tips provided earlier. A clean compressor is less likely to rust or have its parts seized due to grime buildup.


2. Drain All Moisture:

Drain any moisture from the tank. Moisture left inside the tank can cause rust and corrosion during storage.


3. Lubricate the Compressor:

Ensure the compressor is well lubricated before putting it away. This helps prevent parts from sticking and corroding.


4. Cover the Compressor:

Use a cover to protect the compressor from dust and other potential contaminants during storage. Make sure the cover is breathable to prevent moisture buildup.


5. Store in a Dry Place:

Store the compressor in a dry and clean environment. Avoid areas with high humidity levels to prevent rusting.


6. Disconnect Power Source:

For safety, make sure the compressor is disconnected from the power source during storage.


By taking these precautions, you can ensure that your Atlas Copco Ga22 Air Compressor is ready for use the next time you need it, and its lifespan is significantly extended.


https://www.youtube.com/watch?v=tJI5i5moQE0&t=101s&ab_channel=NaeemKhan%28MNAirEngineering%29