Chicago Pneumatic Cps 185 Troubleshooting

As someone who has spent countless hours working with various machinery, I’ve had my fair share of challenges with the Chicago Pneumatic Cps 185 air compressor.


However, rest assured, most issues are often straightforward to troubleshoot and resolve.


Whether it’s a seemingly complicated problem like sudden pressure drops or a simple issue like an overheating motor, understanding the underlying mechanics can make all the difference.


Let’s embark on this Chicago Pneumatic compressor troubleshooting journey together, so you can keep your CPS 185 running smoothly and efficiently.


Chicago Pneumatic Cps 185 Troubleshooting


Chicago Pneumatic Cps 185 Troubleshooting:


Table Of Contents
  1. Chicago Pneumatic Cps 185 Troubleshooting:


If your Chicago Pneumatic CPS 185 Air Compressor is experiencing problems, check the power supply first.

Ensure it’s properly connected and the circuit breaker is not tripped. If the compressor still doesn’t start, examine the air filter and pressure switch.

Clogged filters restrict air flow, causing inefficiencies, while a faulty pressure switch can prevent the compressor from activating.

Additionally, check the unloader valve and thermostat to see if either is stuck or malfunctioning.

If none of these components appear to be at fault, you may need to call a qualified technician.


20 Common Chicago Pneumatic Cps 185 Air Compressor Problems And Solutions:


1. Overheating:

This is a common problem with compressors and can be due to a lack of sufficient airflow around the compressor. The solution is to ensure proper ventilation and regular maintenance.


2. Leaking Air:

If you notice a decrease in performance, this could be due to air leaks. Regular inspection for leaks and promptly sealing them can solve this issue.


3. Pressure Drop:

This can be due to clogged filters. Regular replacement of filters can maintain optimal performance.


4. Oil Leakage:

Look for signs of oil around the compressor. If found, check the seals and replace if necessary.


5. Abnormal Noise:

This can be a sign of internal wear or damage. It’s best to seek professional advice if this occurs.


6. Motor Failure:

If the compressor does not start, the motor may be at fault. The solution can be as simple as replacing the motor.


7. Excessive Vibration:

This can be due to misalignment of parts. Regular maintenance and inspection can prevent this.


8. Unresponsive Pressure Switch:

If the switch doesn’t turn off or on, it may need to be replaced.


9. Compressor won’t start:

Check for power supply and ensure the machine is plugged in correctly.


10. Blown Fuse or Tripped Circuit Breaker:

Replace the fuse or reset the breaker.


11. Worn out belts:

Replace with a new belt.


12. Faulty Regulator:

If the regulator doesn’t maintain adequate pressure, consider replacing it.


13. Low Oil Level:

Check and refill the oil to the recommended level.


14. Clogged Air Filter:

Clean or replace the air filter regularly.


15. Compressor Runs Continuously:

This may be due to a faulty pressure switch or leak in the system.


16. Condensation in the lines:

Drain the air receiver regularly to avoid this.


17. Failure to load/unload:

Check the load/unload valve for any issues.


18. Decreased CFM:

Dirty or worn out valves can lead to decrease in CFM. Cleaning or replacing valves can solve this.


19. Glazing of Belts:

This can be due to the belts being too tight. Adjust the tension of the belts, or replace them if necessary.


20. Pressure Build-Up Too Slow:

This can be due to air leaks or worn out valves. Ensure valves and seals are in good condition and there are no leaks in the system.


Chicago Pneumatic Cps 185 Compressor Fault Codes:

When it comes to Chicago Pneumatic Cps 185 compressors, understanding fault codes can be crucial for efficient operation and maintenance.


Download the Chicago Pneumatic Cps 185 compressor fault codes PDF to view the list of common codes and their descriptions.




Benefits Of Troubleshooting Chicago Pneumatic Cps 185 Air Compressor:

Troubleshooting your Chicago Pneumatic CPS 185 air compressor can yield significant benefits.


First, it enables you to identify potential problems early, preventing minor issues from escalating into costly repairs.


It also ensures optimal performance of the compressor, maximizing its efficiency and lifespan.


Furthermore, troubleshooting can enhance safety by detecting unsafe operating conditions that could lead to accidents or damage.


Finally, it facilitates better understanding of the compressor’s operation, empowering you to use and maintain the machine more effectively.


Maintenance Tips For Your Chicago Pneumatic Cps 185 Air Compressor:

Regular maintenance of your Chicago Pneumatic CPS 185 air compressor can significantly extend its lifespan and maintain optimal performance. Here are few tips:


1. Routine Inspection:

Inspect all components of the air compressor regularly for any signs of wear and tear, corrosion, or damage. This includes hoses, connectors, bolts, and safety valves.


2. Lubrication:

Ensure all moving parts are well lubricated to reduce friction and prevent overheating. Use the recommended grade of oil.


3. Air Filter:

Clean or replace the air filter periodically to maintain the quality of the compressed air and protect the compressor from dust and dirt.


4. Drain Moisture:

Regularly drain the moisture from the air tank to prevent rusting and corrosion.


5. Check Pressure:

Monitor the pressure levels during operation to ensure they are within the recommended range.


Remember, regular maintenance not only prolongs the life of your compressor but also helps it to operate at peak efficiency.


Always refer to the manufacturer’s manual for specific maintenance procedures and intervals.


How Do I Reset My Chicago Pneumatic Cps 185 Compressor?

Resetting your Chicago Pneumatic CPS 185 compressor is a straightforward process that can be done in a few steps:


1. Switch off the compressor and unplug it from the power source.


2. Locate the reset button, typically, it is a red or black button located on the motor casing.


3. Press and hold the reset button for a few seconds.


4. Plug the compressor back into the power source.


5. Switch on the compressor to check if it starts normally.


Remember, the reset button is designed to protect your compressor’s motor from potential damage, so if you find yourself frequently needing to reset the compressor, this may be a sign of an underlying issue that requires attention.


Always follow the manufacturer’s instructions and consult with a professional if you are unsure.


How Do I Know If My Chicago Pneumatic Cps 185 Air Compressor Is Bad?

Detecting a faulty Chicago Pneumatic CPS 185 Air Compressor is relatively straightforward if you know what to look for. Here are some signs that may indicate a problem:


1. Poor Performance:

If the compressor is not producing enough pressure or the air flow is noticeably weaker, this could be a symptom of a faulty compressor.


2. Unusual Noises:

Strange noises such as knocking, rattling or high-pitched squealing often signal internal issues like component failure or misalignment.


3. Excessive Vibration:

While some vibration is normal during operation, excessive or unusual vibration can be a sign of problems within the unit.


4. Overheating:

If the compressor gets unusually hot during use, this could indicate a problem. Overheating can be caused by factors such as poor ventilation, lack of lubrication, or a failing motor.


5. Frequent Resets Needed:

If you find that the compressor’s reset button trips frequently, this may be a sign of electrical issues or a failing motor.


6. Leaks:

Air or oil leaks are serious signs of problems that need immediate attention. If you observe any of these signs, it’s advisable to consult a professional for further troubleshooting and repair.


Always refer to the manufacturer’s manual for more information and recommended maintenance.


What Would Cause An Chicago Pneumatic Cps 185 Air Compressor To Not Build Pressure?

Several factors can contribute to your Chicago Pneumatic CPS 185 air compressor not building pressure:


1. Leakage:

Air leaks in the compressor or the air line can prevent the compressor from building up pressure. Check all connections, hoses, and valves for any signs of leaks.


2. Faulty Check Valve:

When the check valve is not functioning correctly, it can cause air to escape from the tank back into the pump, resulting in low pressure.


3. Worn-out Pump Seals:

Over time, the pump seals can wear out, leading to reduced compression and thereby, lower pressure.


4. Blocked Air Filter:

A clogged air filter can restrict airflow into the compressor, affecting its ability to build pressure.


5. Incorrect Pressure Settings:

If the pressure settings on the compressor are set too low, it will not build the required pressure.


If you’re experiencing issues with your compressor not building pressure, it’s important to diagnose and correct the problem as soon as possible to prevent further damage.


Remember, always refer to the manufacturer’s manual or consult a professional for detailed troubleshooting advice.


Chicago Pneumatic Cps 185 Air Compressor Won’t Start:

If your Chicago Pneumatic CPS 185 air compressor won’t start, there could be several potential reasons:


1. Power Supply:

Check if the compressor is properly plugged into a power source, and ensure the circuit breaker has not tripped.


2. Pressure Switch:

If the pressure switch is malfunctioning or incorrectly set, it may prevent the compressor from starting.


3. Motor Overload:

The motor overload protection could have tripped. If this has occurred, wait for the motor to cool down before pressing the reset button.


4. Damaged Starter Capacitor:

A faulty starter capacitor can lead to the compressor not starting. If the capacitor is swollen or has a burnt odor, it might need to be replaced.


5. Faulty Motor:

If the motor has become damaged or worn out, the compressor may not start.


Should you encounter any of these issues, it is always wise to consult with a professional or refer to the manufacturer’s manual for specific troubleshooting steps.


Properly addressing these issues promptly can prevent further damage and extend the life of your air compressor.


Chicago Pneumatic Cps 185 Air Compressor Not Building Pressure:

If your Chicago Pneumatic CPS 185 air compressor is not building pressure, it could be due to a variety of reasons:


1. Worn-out Seals:

Over time, the seals in the air pump can become worn or damaged, leading to decreased efficiency and inability to build pressure.


2. Faulty Relief Valve:

If the pressure relief valve is stuck open, it will continually release air, preventing the tank from reaching the required pressure.


3. Blocked Intake Filter:

If the intake filter is blocked or dirty, it can restrict the airflow into the compressor, impeding its ability to build pressure.


4. Damaged Pressure Gauge:

A faulty pressure gauge may give incorrect readings, making it seem like the compressor isn’t building pressure when it actually is.


Should you experience any of these issues, it’s important to promptly address them to prevent further damage to your compressor.


Always consult with a professional or refer to the manufacturer’s manual for specific troubleshooting steps and maintenance procedures.


Chicago Pneumatic Cps 185 Air Compressor Reset Button:

The reset button on the Chicago Pneumatic CPS 185 air compressor plays a crucial role in protecting the motor from overheating or overloading.


It’s typically a red or yellow button located on the motor or pressure switch. To use it:


1. First, turn off the compressor and unplug it from the power source.


2. Allow the compressor to cool down for at least 15 minutes if it was running hot.


3. Press the reset button firmly until you hear a click.


4. Once the reset button is pressed, plug the compressor back into the power source and turn it on.


If the compressor frequently trips the reset button or won’t start after pressing the reset button, this may indicate more serious issues that require professional attention.


Always consult the manufacturer’s manual or a certified technician for further advice.


Chicago Pneumatic Cps 185 Air Compressor Won’t Turn On:

If your Chicago Pneumatic CPS 185 air compressor won’t turn on, there could be a number of potential issues causing this:

1. Power Issues:

Ensure that the compressor is properly plugged into a working power source and that there is no issue with the power cord or outlet.


2. Faulty On/Off Switch:

A malfunctioning switch can prevent the compressor from turning on. If the switch doesn’t respond or seems damaged, it may need replacement.


3. Tripped Circuit Breaker:

If the circuit breaker has tripped, the compressor won’t receive power. Reset the breaker and try turning on the compressor again.


4. Malfunctioning Pressure Switch: If the pressure switch is not working correctly, it could be preventing the compressor from starting.


5. Motor Issues: If the motor is damaged or worn out, the compressor may not turn on.


In the event of any of these situations, it is advisable to refer to the manufacturer’s guide or consult a certified technician for further troubleshooting and repair.


Acting promptly can help prevent further damage and enhance the lifespan of your air compressor.


Chicago Pneumatic Cps 185 Air Compressor Check Valve Problem:

If your Chicago Pneumatic CPS 185 air compressor experiences issues with the check valve, several problems might be at hand:


1. Blocked Valve:

The check valve can become blocked due to debris or dirt, preventing air from flowing smoothly.


2. Damaged Valve:

Over time and through use, the valve can suffer wear and tear, leading to malfunctions or inefficiencies.


3. Improper Seating:

If the check valve is not seated correctly, it can cause the compressor to run continuously without building up adequate pressure.


4. Leaky Valve:

A leaky check valve can lead to pressure drops, causing the compressor to struggle to maintain the required pressure.


If you’re experiencing any of these check valve problems, it’s advised to consult the manufacturer’s manual or a professional for proper troubleshooting steps.


It may be necessary to clean, repair, or replace the check valve to ensure optimal function of your air compressor.


Atlas Copco Air Compressor Cleaning Tips:

Maintaining the cleanliness of your Chicago Pneumatic CPS 185 air compressor is crucial for its performance and longevity. Here are some cleaning tips:


1. Routine Inspection:

Regularly check the compressor for signs of dust, dirt, or debris accumulation which may hamper its operation.


2. Cleaning the Intake Filter:

Ensure to clean or replace the intake filter as per the manufacturer’s instructions. A clean filter allows for optimal airflow, increasing the compressor’s efficiency.


3. Cleaning the Exterior:

Wipe down the exterior of the compressor with a clean, dry cloth to prevent dust build-up. Avoid using water or cleaning solutions as they could damage the compressor’s components.


4. Checking the Air Lines:

Periodically examine the air lines for any signs of wear and tear or blockages. Clean them as necessary to maintain an efficient airflow.


5. Draining the Tank:

Regularly drain any condensation from the tank to prevent rusting. Ensure the compressor is disconnected from the power source before you do this.


Remember, always refer to the manufacturer’s manual for more detailed cleaning and maintenance procedures.


If you notice any serious issues during cleaning, consult a professional to avoid inadvertently causing damage.


Chicago Pneumatic Cps 185 Air Compressor Lubrication Tips:

Proper lubrication of your Chicago Pneumatic CPS 185 air compressor is vital for optimal performance and longevity. Here are some lubrication tips:


1. Use the Right Oil:

Always use the lubricating oil recommended by the manufacturer. Using the wrong oil can impair the compressor’s performance and potentially damage its components.


2. Regular Oil Changes:

Regularly change the oil according to the manufacturer’s guidelines to ensure the compressor runs smoothly.


3. Check Oil Level:

Regularly check the oil level using the sight glass. The oil should be halfway up the sight glass. If the level is too low, it may cause the compressor to overheat.


4. Avoid Overfilling:

Overfilling with oil can cause problems such as increased oil carryover. Use the sight glass to ensure the oil is filled to the correct level.


5. Inspect Oil for Contaminants:

Regularly inspect the oil for any signs of contamination. If the oil appears dirty or has a milky appearance, it may need to be replaced.


Remember, always follow the manufacturer’s instructions for specific lubrication procedures and schedules.


If you’re unsure or face any issues during the lubrication process, consult a professional for assistance.


Storing Your Chicago Pneumatic Cps 185 Air Compressor:

Proper storage of your Chicago Pneumatic CPS 185 air compressor is crucial to preserve its functionality and extend its lifespan. Here are some storage tips:


1. Store in a Dry, Clean Space:

Always store the compressor in a clean, dry space to prevent rusting and dust accumulation. Avoid areas with high humidity or extreme temperatures.


2. Disconnect Power:

Ensure the compressor is disconnected from the power source before storing to avoid accidental start-ups.


3. Release Air Pressure:

Before storing, release any air pressure in the tank to prevent damage due to pressure buildup over time.


4. Cover the Compressor:

Cover the compressor with a breathable material to prevent dust accumulation, but make sure it’s not completely airtight to avoid condensation.


5. Regular Checks:

Even when not in use, regular checks are necessary to ensure the machine remains in good condition. Check for any signs of rust, dust accumulation, or oil leaks.


Remember, always refer to the manufacturer’s manual for any specific storage instructions. If you notice any issues during the storage process, consult a professional for guidance.